Metal Framed Suspended Ceiling System

This ceiling system has been developed to make the system cost effective while maintaining the structural stability required for the purpose. The system consists of G.I. “T” section and G.I. Furring Channel interlocked together at right angle to each other, using 6mm thick Hilux board with seamless finish.

mfs-ceiling-system1
mfs-ceiling-system2
 

Installation

Frame Work:

Precoated angles of size 25x25 mm are screw fixed to the perimeter of the wall or partition at the given ceiling level. Main ‘T’ sections 3600mm long, with "H" slots at 150 or 300mm centers in its vertical flange, to hold the cross "T" sections, are suspended from the soffit with the help of rawlplug, soffit cleat and G.I. wire(4mm dia) at 1200mm c/c. These sections also have notch at its both ends to increase the length. Cross "T" sections of 1200mm length with "H" slot in the center and notches at both ends are inserted fixed into the main "T" at 600mm c/c to form a regular grid of 600x1200mm. Cross “T” of 600mm length is inserted fixed into the 1200mm cross "T" to form a regular grid of 600x600mm.

Board Laying:

Hilux boards of size 595x595mm or 595x1195mm are laid into the grid depending on the metal grid size.

Note: clamp down clips should be placed on the back side of the Hilux boards (at least 2 per sides)

Exposed Grid System

Exposed grid system has become more popular because of its flexibility and speedy installation. The system is economical too. The system consists of a pre coated wall angle, main and cross "T", having base of 24mm, with precoated steel, and vertical flange of 35mm, with a bulb at the top. Hilux board cut to size are laid into the grid to provide a neat and clean false ceiling.

mfs-ceiling-system1
mfs-ceiling-system2
 

Installation

Frame Work:

Precoated angles of size 25x25 mm are screw fixed to the perimeter of the wall or partition at the given ceiling level. Main ‘T’ sections 3600mm long, with "H" slots at 150 or 300mm centers in its vertical flange, to hold the cross 'T" sections, are suspended from the soffit with the help of rawlplug, soffit cleat and G.I. wire(4mm dia) at 1200mm c/c. These sections also have notch at its both ends to increase the length. Cross "T" sections of 1200mm length with "H" slot in the center and notches at both ends are inserted fixed into the main "T" at 600mm c/c to form a regular grid of 600x1200mm. Cross "T" of 600mm length is inserted fixed into the 1200mm cross "T" to form a regular grid of 600x600mm.

Board Laying:

Hilux boards of size 595x595mm or 595x1195mm are laid into the grid depending on the metal grid size.

Note: Clamp down clips should be placed on the back side of the Hilux boards (at least 2 per sides)